BREMEN-HH1110KS/KL

BREMEN-HH1110KS/KL

Product Code HH1110KS/KL
Status Call for price

Features

Brand: G-Mac

Status: Stock Available 

Specification:

MAIN FEATURE
Capacity 10KVA /10KW
MODEL

HH1110KS/KL

Brand G-Mac
Brand Origin Germany
Technology IGBT based rectifier true online double conversion
INPUT
Phase  L+N+PE
Rated voltage 208 / 220 / 230 / 240 Vac
Voltage range
  • 110 ~ 176 Vac
  • 110 ~ 300Vac
  • 280 ~ 300 Vac (power limited)
Frequency 50/60Hz(default)±10Hz(Can be set)
Power factor 0.99
OUTPUT
Voltage 208 / 220 / 230 / 240 Vac 
Voltage regulation ±1%
Frequency 50 / 60 Hz±0.1 Hz (battery model)
Waveform Pure sine wave
voltage harmonic distortion(rated input voltage.Raated input frequency) 

<3% (0 ~100% linear load),  ,5% (0 ~100% non linear load)

Inverter overload capability(in normal mode, 25°C)

AC Moode/Battery mode:

  • 30 min@102%-110% Load
  • 10min@110%-130% Load
  • 30s@130%-150% Load
  • 200ms@>150%Load
Transfer Time AC mode switch tom battery mode: 0ms, mains inverter mode switch to bypass mode:4ms
OTHERS
Battery Voltage  24/36Vdc
Charge 1K,2K,3K current 1A(default)1-5A Adjustable, 1KL,2KL,3KL,5A(1-12A)
communication Port RS-232(windows2000/2003/XP/Vista/2008/Linux/nix/Mac, USB(windows famllu& Mac)
Intelligent Slot(option) SNMP/AS400 Relay card/RS485
Relative Humidity 20 ~ 95% (non-condensing)
Temperature Sttorage 15-60°C, Battery:0-40°C
Altitude The altitude should not exceed 1000m, derating above 1000m, up to 40000m max, refer IEC62040
Noise level at 1m ≤ 50 dB
Dimensions (D×W×H) 465mm×190mm×615mm/395mm×192mm×325mm
Net Weight(Kg)  56.5 / 10 (Approx)

Description :

  • IGBT based rectifier true online double conversion
  • Microproccessor control optimizes relaibility
  • DSP technology guaarntees high performance
  • Pure sine wave output
  • Input power factor correction
  • Unity output power factor
  • Extremely wide input voltage window
  • 50Hz/60Hz frequency converter mode
  • ECO and frequency operating voltage possibilities
  • Grapic LCD display with interactive muitingual user interface
  • Digital charger technology provides 0-8A Charging current
  • Adjustble charging current/mode via LCD panel
  • Programmable output voltage 
  • Cold start by battery without without gri Input
  • Generator Compatible 
  • Extension slot for SNMP, Potential-Free Contact, Rremote panel

Question :

1. What is the BREMEN-HH1110KS/KL?

The BREMEN-HH1110KS/KL is a 10kVA True Online Double-Conversion UPS designed to provide uninterrupted and stable power for critical equipment.

2. What is the power capacity of the UPS?

The UPS provides 10kVA /10000W output capacity.

3. What type of UPS technology is used?

It uses True Online Double-Conversion technology for continuous clean power supply.

4. What is the input voltage range?

The UPS supports a wide input voltage range from 110V to 300V AC.

5. What is the output voltage?

The output voltage can typically be configured to 220V, 230V, or 240V AC.

6. Does it provide pure sine wave output?

Yes, the UPS provides pure sine wave output suitable for sensitive electronics.

7. What is the input frequency range?

The UPS supports an input frequency range of 40Hz to 70Hz.

8. What is the output frequency?

The output frequency is 50Hz/60Hz with automatic synchronization.

9. What is the battery configuration?

The UPS uses a 192V DC battery system, usually consisting of sixteen 12V batteries connected in series.

10. What type of batteries are supported?

It supports sealed maintenance-free (SMF) lead-acid batteries.

11. How long is the backup time?

Backup time depends on the connected load and battery condition. Typical backup is several minutes at full load.

12. How long does the battery take to charge?

The battery generally requires around 6–8 hours to reach 90% charge capacity.

13. What is the charging current?

The standard charging current is approximately 1A–4A depending on configuration.

14. What is the output power factor?

The UPS supports output power factor up to 0.9.

15. What is the efficiency of the UPS?

The UPS efficiency is:

  • Up to 95% in online mode
  • Up to 98% in ECO mode

16. Does it support ECO mode?

Yes, the UPS includes ECO mode for energy-saving operation.

17. Does it have an LCD display?

Yes, the UPS features an LED + LCD display showing:

  • Input/output voltage
  • Battery status
  • Load percentage
  • Fault alarms
  • Operating mode

18. What communication ports are available?

The UPS supports:

  • RS232
  • USB
  • SNMP (optional)
  • RS485 (optional)
  • Dry Contact (optional)

19. Does it support remote monitoring?

Yes, remote monitoring is available using an optional SNMP card.

20. Is the UPS generator compatible?

Yes, the UPS is compatible with generators.

21. Does it include surge protection?

Yes, the UPS includes surge and spike protection for connected devices.

22. What protection features are included?

The UPS provides:

  • Overload protection
  • Short-circuit protection
  • Over-temperature protection
  • Battery overcharge protection
  • Surge protection

23. What is the transfer time?

The transfer time is 0ms in online mode.

24. What is the operating temperature range?

The recommended operating temperature is 0°C to 40°C.

25. What humidity level is supported?

The UPS supports humidity up to 95% non-condensing.

26. How noisy is the UPS during operation?

Noise level is generally below 50dB under normal operation.

27. What applications is this UPS suitable for?

It is suitable for:

  • Servers
  • Data centers
  • Networking devices
  • CCTV systems
  • Telecom equipment
  • Medical equipment
  • Industrial electronics

28. How to replace the battery?

  • Turn off the UPS
  • Disconnect mains power
  • Open the battery compartment
  • Remove old batteries
  • Install new batteries with correct polarity
  • Reconnect terminals securely
  • Charge batteries before use

29. What is the approximate weight of the UPS?

The UPS weighs approximately 60–75 kg depending on battery configuration.

30. What is the warranty period?

The standard warranty period is usually 1 year depending on supplier policy.