HAMBURG-HT1106KS

HAMBURG-HT1106KS/KL

Product Code HT 1106KS/KL
Status Call for price

Features

Brand: G-Mac

Status: Stock Available 

Specification:

MAIN FEATURES
Capacity 6KVA/4.8KW
Model HT1106KS/KL
Brand G-Mac
Brand Origin Germany
Technology Online Transformer Based Industrial UPS
INPUT
Phase Single Phase to ground (P+N+E)
Voltage Range

110-300VAC±60%(Load)

160-300VAC±100% (Load)

Frequency Range 40Hz-70Hz
Power Factor 100%(Load)≥0.95
OUTPUT
Output Voltage 220VAC+1%(208,210,230,240 Adjustable)
Voltage Ragulation ±1%
Frequency Range

Synchronize Correction Range-47-53Hz or 57-63Hz

Battery mode-50Hz/60Hz(Adjustable)+0.25Hz

Surge Ratio 3:1 
Todal Hammonic distortion ≤3%THD(Linear load) ≤6%THD(Non-linear load)
Transfer time

ACto DC-0ms

Invertion to bypass-4ms(Standard)

Wavwform pure ssine wave
BATTERY
Battery model Depends on customer requirments
Quantity 3 PCS
Maximun Charging (1-12)AMP- adjustable
Charging Voltage 41.0VDC±1%
WARNING
Battery Model Alarms beeps every 4 seconds
Low Battery Alarms beeps every seconds
Overload Alarms beeps every seconds
Fault Alarms beeps every seconds
SYSTEM FEATURES
Temperature & Humidity

Relative humidity-20-90%

temperature- 0-40°C

Noise <50dBA@ 1 meter
LED/LCD display System state, Load power, battery capacity, utility power mode, battery mode, bypass mode, fault indicator
Communication interface Support windows@2000/2003/XP/Vista/2008, windows 7-8, Linus, Unix
Dimension 384mm×192mm×730mm / 395mm×190mm×325mm
Weight (Kg) 47.80 / 15.80 (Approx)

Description :

Online high frequency CQ series UPS

  1. Pure sine wave output, online zero conversion time
  2. Wide input frequency range: 50Hz/6Hz (adjustable)
  3. Output short circuit protection and overload protection
  4. Full-time lightning protection, noise and surge protection
  5. The LCD screen is to display the status parameters at a glance
  6. The RS232 communication interface is applied
  7. Double-sided circuit board design with higher safety and reliability
  8. Various common technical parameters can be set on the panel
  9. Can be eqiupped with the power monitoring software " Electronic Management Expert" to enable UPS network monmitoring 
  10. Output power 1.0
  11. Super filter function, easy to slove the interface
  12. DSP technology gurrantees high performanve

Application

  1. Depertmental servers
  2. Small LAN
  3. Workstation
  4. IPO
  5. Small medical devies
  6. Small precision electronices instruments
  7. Enterpise Server
  8. High-end servers 
  9. Network Equipment
  10. High ends servers 
  11. Data center room
  12.  Sophisticated equipment

Question :

1. What is the HAMBURG-HT1106KS/kl?

The HAMBURG-HT1106KS/KL is a 6kVA True Online Double-Conversion UPS designed to provide uninterrupted and stable power for sensitive electronic equipment, servers, networking systems, and industrial applications.

2. What is the power capacity of the UPS?

The UPS offers 6kVA / 4800W power capacity depending on model configuration.

3. What is the input voltage range?

The UPS supports a wide input voltage range from 110V to 300V AC.

4. What is the output voltage?

The output voltage can be set to 208V, 220V, 230V, or 240V AC through the LCD panel.

5. Does it provide pure sine wave output?

Yes, the UPS provides pure sine wave output for safe operation of sensitive equipment.

6. What type of UPS technology is used?

It uses True Online Double-Conversion technology for maximum power protection.

7. What is the battery configuration?

The UPS typically uses a 192V DC battery system with sixteen 12V 7Ah batteries connected in series.

8. What is the battery backup time?

Backup time depends on connected load and battery capacity. Standard models generally provide short backup for safe shutdown operations.

9. How long does the battery take to charge?

The battery usually requires around 6–8 hours for full charging after complete discharge.

10. Does it have an LCD display?

Yes, the UPS includes an LED + LCD display showing:

  • Input/output voltage
  • Battery status
  • Load percentage
  • Frequency
  • Fault and alarm information

11. What is the operating frequency range?

The UPS supports an input frequency range of 40Hz to 70Hz.

12. Is the UPS generator compatible?

Yes, the UPS is compatible with generators.

13. What is the output power factor?

The output power factor is up to 1.0 depending on model version.

14. What is the efficiency of the UPS?

The UPS efficiency can reach up to 95% in normal mode and 98% in ECO mode.

15. Does it support ECO mode?

Yes, ECO mode is available for energy-saving operation.

16. What communication ports are available?

The UPS supports:

  • RS232
  • USB
  • SNMP (optional)
  • RS485 (optional)
  • Dry contact card (optional)

17. Can it be monitored remotely?

Yes, remote monitoring is possible using the optional SNMP card.

18. Does it have an Emergency Power Off (EPO) feature?

Yes, the UPS includes an EPO function for emergency shutdown.

19. What is the operating temperature range?

The recommended operating temperature is 0°C to 40°C.

20. What humidity level is supported?

The UPS can operate in environments with humidity up to 95% non-condensing.

21. How noisy is the UPS during operation?

The noise level is generally below 50dB at 1 meter distance.

22. Is rack mounting supported?

Yes, rack-mount and tower versions are available.

23. Can it be used for servers and networking equipment?

Yes, it is suitable for:

  • Servers
  • Data centers
  • Networking devices
  • Telecom equipment
  • Medical systems
  • Industrial electronics

24. What protections are included?

The UPS includes:

  • Overload protection
  • Short-circuit protection
  • Surge protection
  • Battery overcharge protection
  • Over-temperature protection

25. How to replace the battery?

  • Turn off the UPS
  • Disconnect mains power
  • Open battery compartment
  • Remove old batteries
  • Install new batteries with correct polarity
  • Reconnect terminals
  • Charge for at least 8 hours before use

26. What should I do if the UPS overload alarm sounds?

Reduce the connected load immediately and restart the UPS after a few minutes.

27. Can the UPS operate continuously?

Yes, it is designed for continuous online operation.

28. What is the approximate weight of the UPS?

Depending on configuration, the UPS weighs approximately 56–75 kg.

29. What is the warranty period?

The standard warranty period is usually 1–2 years depending on supplier policy.

30. Where can I buy the HAMBURG-HT1106KS?

The UPS can be purchased from authorized UPS distributors and power solution providers.