HAMBURG-HT1103KS

HAMBURG-HT1103KS

Product Code HAMBURG-HT1103KS
Status Call for price

Features

Brand: G-Mac

Status: Stock Available

Specification:

MAIN FEATURES
Capacity 3000VA/2400W
Model HAMBURG-HT1103KS
Brand G-Mac
Brand Origin Germany
Technology Online Transformer Based Industrial UPS
INPUT
Phase Single Phase to ground (P+N+E)
Voltage Range

110-300VAC±60%(Load)

160-300VAC±100% (Load)

Frequency Range 40Hz-70Hz
Power Factor 100%(Load)≥0.95
OUTPUT
Output Voltage 220VAC+1%(208,210,230,240 Adjustable)
Voltage Ragulation ±1%
Frequency Range

Synchronize Correction Range-47-53Hz or 57-63Hz

Battery mode-50Hz/60Hz(Adjustable)+0.25Hz

Surge Ratio 3:1 
Todal Hammonic distortion ≤3%THD(Linear load) ≤6%THD(Non-linear load)
Transfer time

ACto DC-0ms

Invertion to bypass-4ms(Standard)

Wavwform pure ssine wave
BATTERY
Battery model Depends on customer requirments
Quantity 3 PCS
Maximun Charging (1-12)AMP- adjustable
Charging Voltage 41.0VDC±1%
WARNING
Battery Model Alarms beeps every 4 seconds
Low Battery Alarms beeps every seconds
Overload Alarms beeps every seconds
Fault Alarms beeps every seconds
SYSTEM FEATURES
Temperature & Humidity

Relative humidity-20-90%

temperature- 0-40°C

Noise <50dBA@ 1 meter
LED/LCD display System state, Load power, battery capacity, utility power mode, battery mode, bypass mode, fault indicator
Communication interface Support windows@2000/2003/XP/Vista/2008, windows 7-8, Linus, Unix
Dimension 450mm×192mm×335mm
Weight (Kg) 23.7 (Approx)

Description :

Key Features

  • Pure sine wave output with zero transfer time
  • Wide input frequency range: 40–70Hz (adjustable)
  • Output short-circuit and overload protection
  • Full-time lightning, noise, and surge protection
  • LCD screen displays all status parameters clearly
  • RS232 communication interface supported
  • Double-sided PCB design for higher safety and reliability
  • User-adjustable parameters via front panel
  • Compatible with “Electronic Management Expert” network monitoring software
  • Super filter function for interference suppression
  • DSP technology ensures superior performance and efficiency

Applications

  • Departmental Servers & Workstations
  • Small & Medium LAN Systems
  • Enterprise Data Centers
  • Network Switches and Routers
  • IP-PBX and VoIP Systems
  • Industrial Control Systems
  • Laboratory & Research Equipment
  • Hospital Diagnostic and Medical Devices
  • Educational Institutions & Computer Labs
  • CCTV & Security Surveillance Systems
  • POS and Banking Terminals
  • Smart Classrooms and Multimedia Equipment
  • Precision Testing and Measuring Instruments
  • Small Automation Systems
  • Broadcasting and Communication Equipment
  • Sophisticated Office and IT Infrastructure

Question :

1. What is the HAMBURG-HT1103KS?

The HAMBURG-HT1103KS is a 3kVA (2700W) True Online Double-Conversion UPS, designed to provide continuous, clean, and stable power to sensitive electronic equipment.

2. What is the input voltage range?

The UPS accepts an input voltage range from 110V to 300V AC, ensuring stable operation even during voltage fluctuations.

3. What is the output voltage?

The output voltage is 220V AC, suitable for most standard electronic devices.

4. Does it provide pure sine wave output?

Yes, the HAMBURG-HT1103KS delivers a pure sine wave output, making it safe for sensitive equipment like computers, servers, and medical devices.

5. What is the battery configuration?

The UPS uses a 96V DC battery system, typically comprising eight 12V 7Ah batteries connected in series.

6. How long is the battery backup time?

The backup time varies based on the connected load. Under typical conditions, it provides approximately 5.5 minutes of backup at 80% load.

7. What is the charging time for the battery?

The battery typically requires 8 hours to fully charge when the UPS is connected to the mains power supply.

8. Does it have an LCD display?

Yes, the UPS features an LED+LCD display that shows real-time information such as input/output voltage, battery status, load percentage, and fault indicators.

9. What are the audible alarm conditions?

  • Battery discharge: every 2 minutes
  • Low battery: every 6 seconds
  • Overload: continuous beeping
  • Input voltage abnormal: every 2 minutes

10. What is the operating temperature range?

The UPS operates optimally within a temperature range of 0°C to 40°C.

11. Can it be used with generators?

Yes, the HAMBURG-HT1103KS is generator compatible, ensuring stable power supply during generator operation.

12. Is it suitable for home use?

Absolutely. The UPS is ideal for home offices, computers, networking devices, and other sensitive electronics.

13. What is the efficiency of the UPS?

The UPS operates with an efficiency of approximately 88% at 100% load and 90% at 50% load in online mode.

14. Does it have surge protection?

Yes, the UPS provides surge protection, safeguarding connected devices from voltage spikes.

15. How to replace the battery?

  • Turn off the UPS and disconnect it from the mains power supply
  • Remove the battery compartment cover
  • Disconnect the old battery and remove it
  • Install the new battery, ensuring correct polarity
  • Reconnect the battery terminals and replace the cover
  • Charge the new battery for 8 hours before use

16. Can it be installed in a rack?

Yes, the HAMBURG-HT1103KS can be installed in a 19-inch rack using appropriate rack mount kits.

17. What is the warranty period?

The standard warranty period is 1 year from the date of purchase.

18. How to perform firmware updates?

Firmware updates can be performed through the RS232 or SNMP port using the manufacturer's provided software tools.

19. Does it support remote monitoring?

Yes, with the optional SNMP card, the UPS can be monitored remotely over a network.

20. What is the weight of the UPS?

The UPS weighs approximately 25.5 kg, depending on the specific model and configuration.

21. Is it compatible with all devices?

The UPS is compatible with most electronic devices. It is recommended to check the total wattage of connected equipment to ensure it doesn't exceed the UPS's capacity.

22. How to reset the UPS after an overload?

  • Turn off the UPS and disconnect all connected devices
  • Wait for 5–10 minutes
  • Reconnect the devices, ensuring the total load is within the UPS's capacity
  • Turn on the UPS

23. Can it operate in high humidity?

It's recommended to operate the UPS in environments with humidity levels below 90% to prevent potential damage.

24. What to do if the UPS doesn't turn on?

  • Check if the power cord is properly connected
  • Verify that the battery is charged
  • Inspect for any visible faults or error codes on the LCD display
  • Consult the user manual for troubleshooting steps

25. Can it be used in a 3-phase system?

No, the HAMBURG-HT1103KS is designed for single-phase applications only.

26. What is the input frequency range?

The UPS accepts an input frequency range of 40Hz to 70Hz, accommodating various power sources.

27. Does it have an emergency power off (EPO) feature?

Yes, the UPS includes an EPO terminal that allows for immediate shutdown in emergency situations.

28. How to clean the UPS?

  • Turn off and unplug the UPS
  • Wipe the exterior with a dry cloth
  • Avoid using liquid cleaners or aerosols
  • Ensure that no moisture enters the UPS

29. Can it be used in outdoor environments?

The UPS is designed for indoor use only. Exposure to outdoor conditions may damage the unit.

30. Where to purchase the HAMBURG-HT1103KS?

The HAMBURG-HT1103KS can be purchased through authorized dealers or directly from the manufacturer's website.