MAIN FEATURE
Capacity 100KVA/80KW
MODEL  HANOVER-LX33100
Brand G-Mac
Brand Origin Germany
Technology IGBT inverter and output isolation transformer
INPUT
Phase 3Φ+N+PE
Rated voltage 380/400/410
Frequency Range 40-70(Automatically Select Synchonization range according to grib frequency)
Bypass Range ±20%
Battery Voltage 384VDC
Battery Quantity 32PSC(29-32PCS can be adjustable)
OUTPUT
Phase 3Φ+N+PE
Voltage 380/400Vac
Voltage regulation ±1%
Frequency AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1%
Waveform <3%(Linear load); <5%(Non-lineload)
Power factor 0.8/0.9(Option)
Peak Factor 3:1
Overload When the load is less than or equal to 125%, it can be to the bypass output after 10 minutes; when the load is more than 150%, it can turn to the bypass outpot after 1 minutes
OTHERS
Efficiency  AC mode:>92%, ECO mode:>98%
Transfer time 0ms
Protection Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc.
Communication port Standard RS485, Dry contract, USb, for optional:SNMP
Display 7 inches touchable screen
Temperature Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing)
Humidity 0%-90%(No condensing)
IP level IP 20
Noise(dB) <65dB(within 1 meter)
Dimension  D×W×D-739mm×805mm×1405mm
Weight (Kg) 580 Kg

Description :

Applications:

  • Data Centers: Ensures uninterrupted operation for servers and networking equipment.
  • Industrial Systems: Supports CNC machines, automation lines, and production facilities.
  • Commercial Facilities: Provides reliable power for offices, banks, and retail environments.
  • Telecom Systems: Maintains stable operation for telecom base stations and networks.
  • Medical and Banking Systems: Protects sensitive equipment such as diagnostic devices, ATMs, and banking systems.
  • Precision Instruments: Guarantees clean, stable power for laboratories and measuring devices.
  • Other Critical Infrastructure: Ideal for any facility where uninterrupted, high-quality power is essential.

Main Features:

  • IGBT Inverter with Output Isolation Transformer: High efficiency and stable output.
  • Online Double Conversion Technology: Provides continuous, clean sine wave power.
  • Wide Input Voltage Range: Compatible with fluctuating and unstable power conditions.
  • Communication Ports: RS232/RS485 for remote monitoring.
  • Optional SNMP Adapter/Dry Contact: Network-based monitoring and management capability.
  • High Reliability and Performance: Designed for mission-critical applications.
  • External Battery Pack (Optional): Expandable backup time for extended power support.
  • Maintenance Switch: Allows safe service and maintenance without shutting down the load.
  • Advanced Protection Features: Includes overload, short-circuit, surge, and low-battery protection.
  • User-Friendly LCD Display: Shows input/output voltage, battery status, load, and alarms for easy monitoring.

 

Question :

1. What is the capacity of the HANOVER LX-100KVA UPS?
It has a rated capacity of 100KVA / 80KW, suitable for large industrial, IT, and commercial applications.

2. Is the HANOVER LX-100KVA an online UPS?
Yes, it is a double-conversion online UPS designed for uninterrupted clean power.

3. What input voltage does it support?
It supports a wide three-phase input of 380/400/415V AC.

4. What is the output voltage of this UPS?
It provides a stable three-phase 380/400/415V AC pure sine wave output.

5. What is the output power factor?
It delivers a high power factor of 0.9 for maximum load efficiency.

6. Can it stabilize frequency?
Yes, it maintains stable output at 50Hz or 60Hz.

7. What type of batteries does it use?
It uses Sealed Maintenance-Free (SMF) or VRLA lead-acid batteries.

8. What is the required battery voltage?
Typically 384V DC (32 batteries of 12V each in series).

9. How much backup time does it provide?
Standard runtime is 10–15 minutes, extendable with external battery banks.

10. Does the UPS support external batteries?
Yes, external battery cabinets can be added for extended backup.

11. Can it be monitored remotely?
Yes, via RS232, USB, or SNMP/web monitoring interface.

12. Does it have an LCD display?
Yes, a user-friendly LCD/LED panel shows system parameters and alarms.

13. Is it compatible with generators?
Yes, it works seamlessly with diesel and gas generators.

14. What is its efficiency level?
It offers up to 95% efficiency in double-conversion mode.

15. Is the HANOVER LX-100KVA suitable for data centers?
Yes, it is widely used for large-scale data centers and IT infrastructure.

16. Can it support industrial applications?
Yes, it powers CNC machines, automation systems, and industrial production lines.

17. Is it safe for medical use?
Yes, it provides clean and reliable power for hospitals, labs, and diagnostic equipment.

18. What protection features are included?
It provides overload, short-circuit, surge, low battery, and over/under-voltage protection.

19. Does it support bypass mode?
Yes, both automatic and manual bypass are available.

20. Does it have auto-restart capability?
Yes, it automatically restarts when utility power is restored.

21. What is the expected battery life?
3–5 years depending on usage and environmental conditions.

22. How often should batteries be replaced?
Typically every 3 years under normal usage.

23. What is the noise level of the UPS?
It operates below 62dB, depending on load and cooling fans.

24. Does it require professional installation?
Yes, professional installation is recommended for safe and efficient operation.

25. Can its backup time be expanded in the future?
Yes, additional external battery banks can be installed.

26. Does it feature smart battery charging?
Yes, intelligent battery charging technology increases battery lifespan.

27. Is the UPS easy to maintain?
Yes, it requires only regular battery checks and dust protection.

28. What is the approximate weight of the HANOVER LX-100KVA UPS?
It weighs around 800–1000 kg depending on model and configuration.

29. Where is the HANOVER LX-100KVA commonly used?
It is used in telecom, industries, banks, hospitals, government, and large IT facilities.

30. Why should I choose the HANOVER LX-100KVA UPS?
Because it provides maximum reliability, high efficiency, flexible backup options, and advanced monitoring for mission-critical power needs.