| MAIN FEATURE | |
|---|---|
| Capacity | 20KVA/16KW |
| MODEL | HANOVER-LX3320 |
| Brand | G-Mac |
| Brand Origin | Germany |
| Technology | IGBT inverter and output isolation transformer |
| INPUT | |
| Phase | 3Φ+N+PE |
| Rated voltage | 380/400/410 |
| Frequency Range | 40-70(Automatically Select Synchonization range according to grib frequency) |
| Bypass Range | ±20% |
| Battery Voltage | 384VDC |
| Battery Quantity | 32PCS (29-32PCS can be adjustable) |
| OUTPUT | |
| Phase | 3Φ+N+PE |
| Voltage | 380/400Vac |
| Voltage regulation | ±1% |
| Frequency | AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1% |
| Waveform | <3%(Linear load); <5%(Non-lineload) |
| Power factor | 0.8/0.9(Option) |
| Peak Factor | 3:1 |
| Overload | When the load is less than or equal to 125%, it can be to the bypass output after 10 minutes; when the load is more than 150%, it can turn to the bypass outpot after 1 minutes |
| OTHERS | |
| Efficiency | AC mode:>92%, ECO mode:>98% |
| Transfer time | 0ms |
| Protection | Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc. |
| Communication port | Standard RS485, Dry contract, USb, for optional:SNMP |
| Temperature | Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing) |
| Humidity | 0%-90%(No condensing) |
| IP level | IP 21 |
| Noise(dB) | <65dB(within 1 meter) |
| Dimension | D×W×D-560mm×370mm×900mm |
| Weight (Kg) | 130 Kg |
1. What type of UPS is the HANOVER LX-20KVA?
It is an online double-conversion UPS designed for critical applications requiring continuous and stable power.
2. What is the capacity of the LX-20KVA UPS?
The UPS provides 20KVA / 20KW of power, suitable for medium to large loads.
3. What is the main application of the LX-20KVA UPS?
It is used in data centers, hospitals, telecom networks, banks, industries, and government facilities.
4. What is the input voltage range of the UPS?
It supports a wide input voltage window to minimize unnecessary battery usage.
5. What is the output voltage of the LX-20KVA UPS?
It delivers a stable 220/230/240V AC depending on region.
6. What is the operating frequency?
The UPS works on 50Hz or 60Hz with automatic frequency detection.
7. What power factor does the LX-20KVA offer?
It is designed with a 0.9 or higher power factor for efficient performance.
8. What efficiency does the UPS provide?
The efficiency is up to 95% or more, reducing energy losses.
9. What type of batteries does it use?
The UPS uses sealed maintenance-free VRLA batteries or equivalent.
10. How long can the UPS provide backup?
Backup duration depends on the connected load and the configured battery capacity.
11. Are the batteries hot-swappable?
Yes, the UPS supports hot-swappable battery modules for easy maintenance.
12. How long does it take to recharge the batteries?
Batteries typically recharge within 4–8 hours to 90% capacity.
13. What protection features are included?
It has overload, short-circuit, over-temperature, surge, and low battery protection.
14. How does it protect against power surges?
The double-conversion technology ensures spike and surge isolation for connected devices.
15. What is the transfer time during outages?
It provides zero transfer time, ensuring uninterrupted power supply.
16. Does the LX-20KVA have an LCD display?
Yes, it features a user-friendly LCD panel showing real-time status and alarms.
17. Can it be monitored remotely?
Yes, it supports USB, RS232, and SNMP/network cards for remote management.
18. Does the UPS provide audible alarms?
Yes, it gives beeps and alerts for low battery, overload, or system faults.
19. Can I connect this UPS to a generator?
Yes, it is generator-compatible and works smoothly with backup gensets.
20. What is the ideal installation environment?
Install in a cool, dry, dust-free, and well-ventilated area.
21. What is the operating temperature range?
It typically operates between 0°C to 40°C with <95% non-condensing humidity.
22. How often should the batteries be replaced?
Batteries last about 3–5 years depending on usage and environment.
23. What routine maintenance is recommended?
Regular battery testing, ventilation checks, and cleaning are suggested.
24. Can the UPS run in parallel?
Yes, some LX-20KVA models support parallel redundancy for higher capacity.
25. What are common fault messages?
Low Battery
Overload
Over-temperature
Input Failure
Inverter Fault
26. How should I troubleshoot a UPS that won’t start?
Check input power, fuses, and battery connections. Contact service if unresolved.
27. What is the noise level during operation?
The UPS has low acoustic noise due to efficient cooling fans.
28. Does it comply with safety standards?
Yes, it complies with international UPS standards for safety and performance.
29. What warranty is provided?
Typically, 2–3 years for UPS and 1 year for batteries (region-specific).
30. Why should I choose the HANOVER LX-20KVA Online UPS?
Because it offers high reliability, advanced protection, long backup, and efficiency, making it ideal for mission-critical power needs.