HANOVER-LX33200

HANOVER-LX33200

Product Code HANOVER-LX33200
Status Call for price

Features

Brand: G-Mac

Status: Stock Available

Specification:

MAIN FEATURE
Capacity 200KVA/160KW
MODEL  HANOVER-LX33200
Brand G-Mac
Brand Origin Germany
Technology IGBT inverter and output isolation transformer
INPUT
Phase 3Φ+N+PE
Rated voltage 380/400/410
Frequency Range 40-70(Automatically Select Synchonization range according to grib frequency)
Bypass Range ±20%
Battery Voltage 384VDC
Battery Quantity 32PCS (29-32PCS can be adjustable)
OUTPUT
Phase 3Φ+N+PE
Voltage 380/400Vac
Voltage regulation ±1%
Frequency AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1%
Waveform <3%(Linear load); <5%(Non-lineload)
Power factor 0.8/0.9(option)
Pack Factor 3:1
Overload When the load is less than or equal to 125%, it can be to the bypass output after 10 minutes; when the load is more than 150%, it can turn to the bypass outpot after 1 minutes
OTHERS
Efficiency  AC mode:>92%, ECO mode:>98%
Transfer time 0ms
Protection Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc.
Communication port Standard RS485, Dry contract, USb, for optional:SNMP
Temperature Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing)
Humidity 0%-90%(No condensing)
IP level IP 20
Noise(dB) <65dB(within 1 meter)
Dimension  D×W×D-865mm×1285mm×1600mm
Weight (Kg) 1180 Kg

Description :

Applications:

  • Data Centers: Ensures uninterrupted operation for servers and networking equipment.
  • Industrial Systems: Supports CNC machines, automation lines, and production facilities.
  • Commercial Facilities: Provides reliable power for offices, banks, and retail environments.
  • Telecom Systems: Maintains stable operation for telecom base stations and networks.
  • Medical and Banking Systems: Protects sensitive equipment such as diagnostic devices, ATMs, and banking systems.
  • Precision Instruments: Guarantees clean, stable power for laboratories and measuring devices.
  • Other Critical Infrastructure: Ideal for any facility where uninterrupted, high-quality power is essential.

Main Features:

  • IGBT Inverter with Output Isolation Transformer: High efficiency and stable output.
  • Online Double Conversion Technology: Provides continuous, clean sine wave power.
  • Wide Input Voltage Range: Compatible with fluctuating and unstable power conditions.
  • Communication Ports: RS232/RS485 for remote monitoring.
  • Optional SNMP Adapter/Dry Contact: Network-based monitoring and management capability.
  • High Reliability and Performance: Designed for mission-critical applications.
  • External Battery Pack (Optional): Expandable backup time for extended power support.
  • Maintenance Switch: Allows safe service and maintenance without shutting down the load.
  • Advanced Protection Features: Includes overload, short-circuit, surge, and low-battery protection.
  • User-Friendly LCD Display: Shows input/output voltage, battery status, load, and alarms for easy monitoring.

Question :

1. What is the capacity of the HANOVER LX-33 200KVA UPS?
It provides 200KVA / 160KW, suitable for large-scale industrial, commercial, and IT applications.

2. Is the HANOVER LX-33 200KVA an online UPS?
Yes, it is a double-conversion online UPS ensuring uninterrupted, stable, and clean power.

3. What input voltage does it support?
It supports a three-phase input of 380/400/415V AC.

4. What is the output voltage of this UPS?
It delivers stable three-phase 380/400/415V AC pure sine wave output.

5. What is the output power factor?
It provides a high power factor of 0.9 for efficient power delivery.

6. Can it stabilize frequency fluctuations?
Yes, it maintains stable 50Hz or 60Hz output frequency.

7. What type of batteries does it use?
It uses Sealed Maintenance-Free (SMF) or VRLA lead-acid batteries.

8. What is the required battery voltage?
Typically 384V DC (32 batteries of 12V each in series).

9. How long is the backup time?
Standard runtime is 10–15 minutes, extendable with external battery banks.

10. Does it support external batteries?
Yes, additional external battery cabinets can be connected for extended runtime.

11. Can the UPS be monitored remotely?
Yes, it supports RS232, USB, and optional SNMP/network management.

12. Does it have an LCD display?
Yes, an intelligent LCD/LED panel displays input/output voltage, load, battery status, and alarms.

13. Is it compatible with generators?
Yes, it works seamlessly with diesel or gas generators.

14. What is the efficiency rating?
It provides up to 95% efficiency in online double-conversion mode.

15. Is it suitable for data centers?
Yes, widely used for large-scale server rooms and IT infrastructure.

16. Can it support industrial machinery?
Yes, it powers CNC machines, automation lines, and production systems.

17. Is it safe for medical and banking equipment?
Yes, it provides stable power for hospitals, labs, ATMs, and banking systems.

18. What protection features are included?
It includes overload, short-circuit, surge, over/under-voltage, and low-battery protections.

19. Does it include bypass functionality?
Yes, both automatic and manual bypass options are available.

20. Does it support auto-restart?
Yes, the UPS automatically restarts when utility power returns.

21. What is the expected battery life?
Batteries typically last 3–5 years depending on usage and environment.

22. How often should batteries be replaced?
Every 3 years under normal operating conditions.

23. What is the noise level of this UPS?
It operates below 65dB under normal load conditions.

24. Does it require professional installation?
Yes, professional installation is recommended due to its high capacity.

25. Can the backup capacity be expanded?
Yes, additional external battery packs can be connected to extend runtime.

26. Does it feature intelligent battery charging?
Yes, it has smart battery charging technology for longer battery lifespan.

27. Is it easy to maintain?
Yes, routine maintenance includes battery checks and dust cleaning.

28. What is the approximate weight of the HANOVER LX-33 200KVA UPS?
It weighs around 1400–1800 kg depending on configuration.

29. Where is this UPS commonly used?
It is used in industries, banks, hospitals, telecom, data centers, and government facilities.

30. Why choose HANOVER LX-33 200KVA UPS?
Because it provides high reliability, efficiency, advanced monitoring, and flexible battery support for mission-critical applications.