| MAIN FEATURE | |
|---|---|
| Capacity | 10KVA/8KW |
| MODEL | SAARLAND-LX3110 |
| Brand | G-Mac |
| Brand Origin | Germany |
| Technology | IGBT inverter and output isolation transformer |
| INPUT | |
| Phase | 3Φ4W+PE |
| Rated voltage | 380±20% |
| Frequency Range | 45-66(Automatically Select Synchonization range according to grib frequency) |
| Battery Voltage | 192VDC |
| OUTPUT | |
| Phase | 3Φ+N+PE |
| Voltage | 220/230/240, Isolated transformer output |
| Voltage regulation | ±1% |
| Frequency | AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1% |
| Waveform | Sine Wave, THD<3% |
| Power factor | 0.8/0.9(Option) |
| Crest Factor | >3:1 |
| Overload | 125% load keep 10min, 150% load keep 60s |
| OTHERS | |
| Output ways | Terminal Block |
| Parallel function | Yes(for optional) |
| Manual maintance | with no transfer time bypass maintenance switch |
| Backup Time | As per required |
| Efficiency | AC mode:>90%(full loads) |
| Transfer time | 0ms |
| Protection | Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc. |
| Communication function | Standard RS232/RS485interface, support for power monitor software |
| Temperature | Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing) |
| Humidity | 0%-90%(No condensing) |
| Alarm | battery low voltage, mains abnormal, overload, UPS fault, over temperature protection |
| Noise(dB) | <60dB(within 1 meter) |
| SNMP(optional) | Cab be network monitored by SNMP adapter |
| Dimension | D×W×H-596mm×305mm×1065mm |
| Weight (Kg) | 121 Kg |
1. What is the capacity of the SAARLAND 10KVA UPS?
It provides 10KVA / 8KW capacity, ideal for medium to large electrical loads.
2. Is the SAARLAND 10KVA UPS an online type?
Yes, it is a double-conversion online UPS for uninterrupted clean power.
3. What is the input voltage range of this UPS?
It works on a wide range of 208–240V AC single/three-phase input.
4. What output voltage does it deliver?
It supplies a stable 220/230V AC pure sine wave output.
5. How does the UPS protect sensitive equipment?
It regulates voltage, filters harmonics, and protects against surges and spikes.
6. Can it handle frequency instability?
Yes, the UPS stabilizes frequency at 50Hz or 60Hz.
7. What is the power factor of SAARLAND 10KVA UPS?
It usually has a high power factor around 0.8–0.9, ensuring efficient load support.
8. How long can it provide backup power?
Backup time depends on battery configuration, typically 15–30 minutes with internal batteries, extendable with external banks.
9. Does it support external batteries?
Yes, external battery packs can be connected for longer runtime.
10. What battery type does it use?
Sealed Maintenance-Free (SMF) lead-acid or VRLA batteries.
11. What is the typical battery voltage?
The system usually requires 192V–240V DC (16–20 batteries in series).
12. Can I monitor the UPS remotely?
Yes, via USB, RS232, or SNMP card for LAN/WAN monitoring.
13. Does it have an LCD display?
Yes, an LCD panel shows input/output, battery status, load %, and alarms.
14. Can it work with generators?
Yes, it is fully compatible with diesel or gas generators.
15. What is the efficiency rating?
It offers 90–95% efficiency depending on load conditions.
16. Is the SAARLAND 10KVA UPS suitable for IT equipment?
Yes, it is ideal for data centers, servers, and networking equipment.
17. Can it be used for industrial machines?
Yes, it supports CNC machines, laboratory equipment, and production systems.
18. Is it safe for medical applications?
Yes, it ensures stable power for hospitals and diagnostic equipment.
19. Does it have overload protection?
Yes, the UPS automatically trips or shifts to bypass mode during overload.
20. What protections are included?
Overload, short circuit, over-voltage, under-voltage, battery low, and surge protection.
21. How much noise does it produce?
It operates at less than 55dB, with cooling fans active under heavy load.
22. Can it auto-restart after power comes back?
Yes, it has auto-restart functionality after utility recovery.
23. Is it easy to maintain?
Yes, only periodic battery checks and dust cleaning are required.
24. What is the average battery lifespan?
3–5 years depending on usage and environment.
25. How often should I replace the batteries?
Every 3 years in normal conditions, earlier in high-temperature areas.
26. Can I expand its backup time later?
Yes, by adding more external batteries or battery cabinets.
27. Does it have bypass mode?
Yes, it includes both automatic and manual bypass options.
28. What is the typical weight of the SAARLAND 10KVA UPS?
Around 90–120 kg depending on battery configuration.
29. Where is this UPS commonly used?
In banks, hospitals, data centers, offices, industries, and telecom sites.
30. Why should I choose SAARLAND 10KVA UPS?
Because it delivers high efficiency, reliable protection, flexible battery options, and advanced monitoring for critical loads.