| MAIN FEATURE | |
|---|---|
| Capacity | 30KVA/24KW |
| MODEL | SAARLAND-LX3130 |
| Brand | G-Mac |
| Brand Origin | Germany |
| Technology | IGBT inverter and output isolation transformer |
| INPUT | |
| Phase | 3Φ4W+PE |
| Rated voltage | 380±20% |
| Frequency Range | 45-66(Automatically Select Synchonization range according to grib frequency) |
| Battery Voltage | 384VDC |
| OUTPUT | |
| Phase | 3Φ+N+PE |
| Voltage | 220/230/240, Isolated transformer output |
| Voltage regulation | ±1% |
| Frequency | AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1% |
| Waveform | Sine Wave, THD<3% |
| Power factor | 0.8/0.9(Option) |
| Crest Factor | >3:1 |
| Overload | 125% load keep 10min, 150% load keep 60s |
| OTHERS | |
| Output ways | Terminal Block |
| Parallel function | No |
| Manual maintance | with no transfer time bypass maintenance switch |
| Backup Time | As per required |
| Efficiency | AC mode:>90%(full loads) |
| Transfer time | 0ms |
| Protection | Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc. |
| Communication function | Standard RS232/RS485interface, support for power monitor software |
| Temperature | Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing) |
| Humidity | 0%-90%(No condensing) |
| Alarm | battery low voltage, mains abnormal, overload, UPS fault, over temperature protection |
| Noise(dB) | <60dB(within 1 meter) |
| SNMP(optional) | Cab be network monitored by SNMP adapter |
| Dimension | D×W×H-700mm×405mm×955mm |
| Weight (Kg) | 280 Kg |
Applications:
1. What is the capacity of the SAARLAND 30KVA UPS?
It has a capacity of 30KVA / 24KW, suitable for large offices, industries, and data centers.
2. Is the SAARLAND 30KVA an online UPS?
Yes, it is a double-conversion online UPS that delivers continuous clean power.
3. What input voltage range does it support?
It supports a wide input range, typically 380/400/415V three-phase AC.
4. What is the output voltage of this UPS?
It provides a stable 380/400/415V three-phase pure sine wave output.
5. Can it handle frequency fluctuations?
Yes, it regulates frequency at 50Hz or 60Hz depending on system configuration.
6. What is the output power factor?
The UPS offers a power factor of 0.9, delivering more usable power to loads.
7. How long is the backup time?
Standard runtime is 10–20 minutes, extendable with external battery banks.
8. Does it support external batteries?
Yes, external battery cabinets can be added for extended backup.
9. What battery voltage does it require?
It typically uses 384V DC (32 batteries in series, 12V each).
10. What type of battery is used?
Sealed Maintenance-Free (SMF) or VRLA lead-acid batteries are compatible.
11. Can the UPS be monitored remotely?
Yes, via RS232, USB, or optional SNMP/web management card.
12. Does the SAARLAND 30KVA UPS have an LCD display?
Yes, it has an advanced LCD/LED panel showing real-time status and alarms.
13. Is it compatible with generators?
Yes, it operates seamlessly with diesel or gas generators.
14. What efficiency does the UPS provide?
It achieves up to 95% efficiency in online double-conversion mode.
15. Is it suitable for IT applications?
Yes, it is perfect for data centers, large server rooms, and networking systems.
16. Can it support industrial applications?
Yes, it supports CNC, automation systems, and heavy industrial equipment.
17. Is it safe for medical equipment?
Yes, it provides clean, uninterrupted power for hospitals and laboratories.
18. What protection features are included?
It includes overload, short-circuit, surge, battery low, and input/output voltage protections.
19. Does it have bypass mode?
Yes, both automatic and manual bypass functions are available.
20. What is the expected battery life?
The batteries last 3–5 years depending on environment and usage.
21. How often should the batteries be replaced?
Every 3 years under normal conditions, sooner in high-temperature environments.
22. Does the UPS have auto-restart functionality?
Yes, it automatically restarts when utility power returns.
23. What is the noise level?
It operates below 58dB, with fans adjusting speed based on load.
24. Does it require professional installation?
Yes, expert installation is recommended for safety and correct setup.
25. Can its backup be expanded in the future?
Yes, backup can be extended with additional external battery banks.
26. Does it feature intelligent charging?
Yes, it uses smart battery charging technology for extended battery life.
27. Is the SAARLAND 30KVA UPS easy to maintain?
Yes, routine maintenance includes checking batteries and airflow clearance.
28. What is the approximate weight of the unit?
It weighs between 200–260 kg depending on the battery configuration.
29. Where is the SAARLAND 30KVA UPS commonly used?
It is widely used in industries, banks, telecoms, hospitals, and government facilities.
30. Why choose the SAARLAND 30KVA UPS?
Because it ensures reliable high-capacity power, advanced monitoring, flexible battery options, and maximum protection for critical operations.