| MAIN FEATURE | |
|---|---|
| Capacity | 40KVA/32KW |
| MODEL | SAARLAND-LX3140 |
| Brand | G-Mac |
| Brand Origin | Germany |
| Technology | IGBT inverter and output isolation transformer |
| INPUT | |
| Phase | 3Φ4W+PE |
| Rated voltage | 380±20% |
| Frequency Range | 45-66(Automatically Select Synchonization range according to grib frequency) |
| Battery Voltage | 384VDC |
| OUTPUT | |
| Phase | 3Φ+N+PE |
| Voltage | 220/230/240, Isolated transformer output |
| Voltage regulation | ±1% |
| Frequency | AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1% |
| Waveform | Sine Wave, THD<3% |
| Power factor | 0.8/0.9(Option) |
| Crest Factor | >3:1 |
| Overload | 125% load keep 10min, 150% load keep 60s |
| OTHERS | |
| Output ways | Terminal Block |
| Parallel function | No |
| Manual maintance | with no transfer time bypass maintenance switch |
| Backup Time | As per required |
| Efficiency | AC mode:>90%(full loads) |
| Transfer time | 0ms |
| Protection | Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc. |
| Communication function | Standard RS232/RS485interface, support for power monitor software |
| Temperature | Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing) |
| Humidity | 0%-90%(No condensing) |
| Alarm | battery low voltage, mains abnormal, overload, UPS fault, over temperature protection |
| Noise(dB) | <60dB(within 1 meter) |
| SNMP(optional) | Cab be network monitored by SNMP adapter |
| Dimension | D×W×H-740mm×560mm×1200mm |
| Weight (Kg) | 310 Kg |
1. What type of UPS is SAARLAND-LX33140?
It is a three-phase online double-conversion UPS providing stable and uninterrupted power for industrial and commercial applications.
The UPS is rated at 140 KVA, suitable for medium-to-large power systems.
Yes, it ensures zero transfer time switching to battery mode during power failures.
It uses a 384V DC lead-acid or lithium battery, depending on configuration.
The UPS provides a stable three-phase 380V AC output.
The output power factor is 0.8, ensuring optimal efficiency for connected loads.
Yes, the SAARLAND-LX33140 supports N+X parallel redundancy for scalability and reliability.
It achieves up to 90% online efficiency, reducing energy loss.
The UPS can handle 125% overload for 1 minute and 150% for 200 ms before bypassing.
It comes with RS232, RS485, optional SNMP, and dry contacts for monitoring.
Yes, the cold-start function allows the UPS to power up directly from the battery.
It operates safely between 0°C to 40°C.
The UPS functions in 0%–95% non-condensing humidity.
Yes, it protects connected equipment from over-voltage, short circuit, and surge.
It complies with IEC/EN62040-1, IEC/EN60950-1, and IEC/EN62040-2 standards.
Yes, it has a wide input voltage range to handle unstable mains supply.
Absolutely, it is ideal for factories, data centers, hospitals, and commercial buildings.
Yes, it provides true online double-conversion pure sine wave output.
The intelligent battery management system monitors battery health and extends battery life.
It comes with user-friendly manuals and can be installed by certified technicians.
Yes, using SNMP or network management systems, remote monitoring is possible.
Backup depends on battery capacity; typically, 10–30 minutes for standard batteries.
Regular checks include battery inspection, cooling fan cleaning, and load testing.
Yes, it features audio and visual alarms for overloads, battery issues, or system faults.
Yes, it delivers stable, clean power suitable for servers, networking, and medical equipment.
It operates quietly at less than 55 dB, making it suitable for office environments.
Yes, multiple UPS units can be synchronized for redundancy and load sharing.
Typically, it comes with a 1–2 year manufacturer warranty, depending on purchase.
Yes, it can operate at up to 1500 meters above sea level without derating.
It is available through authorized distributors like TNS Engineering Ltd. and other industrial UPS suppliers.