| MAIN FEATURE | |
|---|---|
| Capacity | 15KVA/12KW |
| MODEL | SAARLAND-LX3115 |
| Brand | G-Mac |
| Brand Origin | Germany |
| Technology | IGBT inverter and output isolation transformer |
| INPUT | |
| Phase | 3Φ4W+PE |
| Rated voltage | 380±20% |
| Frequency Range | 45-66(Automatically Select Synchonization range according to grib frequency) |
| Battery Voltage | 192VDC |
| OUTPUT | |
| Phase | 3Φ+N+PE |
| Voltage | 220/230/240, Isolated transformer output |
| Voltage regulation | ±1% |
| Frequency | AC mode: tracking bypass input in synchronous State, Battery mode:50/60Hz±0.1% |
| Waveform | Sine Wave, THD<3% |
| Power factor | 0.8/0.9(Option) |
| Crest Factor | >3:1 |
| Overload | 125% load keep 10min, 150% load keep 60s |
| OTHERS | |
| Output ways | Terminal Block |
| Parallel function | Yes(for optional) |
| Manual maintance | with no transfer time bypass maintenance switch |
| Backup Time | As per required |
| Efficiency | AC mode:>90%(full loads) |
| Transfer time | 0ms |
| Protection | Output short circuit protection, overload, over temperature, battery low-voltage, over/under voltage, fan fault, etc. |
| Communication function | Standard RS232/RS485interface, support for power monitor software |
| Temperature | Working (0°C-55°C), Stroage(-5°C-60°C)-(No condensing) |
| Humidity | 0%-90%(No condensing) |
| Alarm | battery low voltage, mains abnormal, overload, UPS fault, over temperature protection |
| Noise(dB) | <60dB(within 1 meter) |
| SNMP(optional) | Cab be network monitored by SNMP adapter |
| Dimension | D×W×H-596mm×305mm×1065mm |
| Weight (Kg) | 146 Kg |
1. What is the capacity of the SAARLAND 15KVA UPS?
It has a 15KVA / 12KW capacity, suitable for medium to large load requirements.
2. Is the SAARLAND 15KVA an online UPS?
Yes, it is a true double-conversion online UPS ensuring continuous and clean power.
3. What input voltage range does this UPS support?
It works on a wide input voltage range of 208–240V single or three-phase.
4. What is the output voltage of the SAARLAND 15KVA UPS?
It delivers pure sine wave output, typically 220/230V AC.
5. Can it stabilize frequency fluctuations?
Yes, it maintains a stable 50Hz or 60Hz frequency output.
6. What is the output power factor?
The UPS provides a high power factor of 0.8–0.9 for efficient performance.
7. How long backup can it provide?
With internal batteries, it offers 15–30 minutes, extendable with external battery banks.
8. Does it support external batteries?
Yes, external SMF or VRLA battery packs can be connected for longer backup.
9. What battery voltage is required?
Typically 192V–240V DC (16–20 batteries in series, 12V each).
10. What type of battery does it use?
Sealed Maintenance-Free (SMF) lead-acid batteries are recommended.
11. Can I monitor the UPS remotely?
Yes, via RS232, USB, or optional SNMP card for LAN/WAN monitoring.
12. Does it have an LCD display?
Yes, it has an intelligent LCD/LED display showing input, output, load, and battery status.
13. Is the SAARLAND 15KVA UPS generator compatible?
Yes, it can work efficiently with diesel or gas generators.
14. What is the efficiency rating?
It offers 90–95% efficiency depending on load.
15. Is this UPS suitable for IT applications?
Yes, it is widely used for servers, networks, and data centers.
16. Can it support industrial machines?
Yes, it is suitable for CNC machines, automation, and laboratory equipment.
17. Is it safe for medical equipment?
Yes, it ensures uninterrupted and clean power for hospital devices.
18. What safety protections are included?
It has overload, short-circuit, over-voltage, low battery, and surge protection.
19. Does it have bypass options?
Yes, it includes both manual and automatic bypass.
20. What is the average backup battery lifespan?
Batteries last 3–5 years depending on usage and conditions.
21. Can the SAARLAND 15KVA UPS auto-restart?
Yes, it restarts automatically when utility power is restored.
22. How noisy is the UPS?
It operates below 55dB, with cooling fan noise under heavy load.
23. Does it require professional installation?
Yes, professional setup is recommended for safety and performance.
24. How often should the batteries be replaced?
Every 3 years under normal usage, earlier in high-temperature environments.
25. Can its backup time be expanded later?
Yes, additional external battery cabinets can be added.
26. Does the UPS have intelligent charging?
Yes, it features smart battery management for longer life.
27. Is it easy to maintain?
Yes, minimal maintenance is needed, mainly for batteries and ventilation.
28. What is the approximate weight of the SAARLAND 15KVA UPS?
Weight varies by model, usually 110–150 kg without batteries.
29. Where is the SAARLAND 15KVA UPS commonly used?
In banks, hospitals, data centers, telecom, offices, and industrial plants.
30. Why should I choose SAARLAND 15KVA UPS?
Because it ensures reliable backup, high efficiency, strong protections, and flexible battery support for critical loads.